• head_banner

Smart Busway monitoring solution

Smart busway monitoring solution

Application

It is necessary to real-time monitor energy consumption and power quality of end load in smart track busway. Data can be uploaded to monitoring system by local touch screen through RS485 and it can realize real-time monitoring of the whole power distribution system.At the same time,it can monitor real-time temperature at the busway connector and plug-in box interface to ensure safe and reliable operation of the busway. 

Structure

1
2
3
4
5
6

Main Functions

AMB100 or AMB110 is usually installed in the busbar start box and plug-in box

Measurement:AC or DC busbar voltage,current,harmonics and other parameters.

Realize temperature monitoring of the busbar plug interface

AMB200 is usually installed at the connector of the dense AC busbar,and can monitor temp. And humidity at the connector.

Communication:LoRa or RS485

Product Selection

Name Pic Model Main Function
HMI  7 ATP010kt 1.10 inch touch screen2.Real-time monitoring and display voltage,current,power,energy,power quality,switch status,wave curve,etc. of the busbar

3.monitoring device alarm,communication and other parameters can be configured on the screen.

4.RS485 and 1 Ethernet,and data can uploaded by RS485 or RJ45

AC start box monitoring module  8 AMB100-A-P1 1.Installation:DIN Rail 35mm2.Measurement:3 phase electrical parameters,2DI2DO,8 temp.,1 leakage current,1 temp. and humidity

3.Communication:1 in 1 out type RJ45 interface(Modbus protocol)

 

AC plug-in box monitoring module  9 AMB110-A-P1 1.Installation:DIN Rail 35mm

2. Measurement:3 phase electrical parameters,2DI2DO,4 temp.,1 leakage current,1 temp. and humidity

3. Communication:1 in 1 out type RJ45 interface(Modbus protocol)

DC start box monitoring module  10 AMB100-D-P1 1.Installation:DIN Rail 35mm

2.Measurement:1 DC circuit electrical parameters,4DI2DO,8 temp.,1 leakage current,1 temp. and humidity

3.±12V output to power hall current sensor

4.Communication:1 in 1 out type RJ45 interface(Modbus protocol)

DC plug-in box monitoring module AMB110-D-P1 1.Installation:DIN Rail 35mm

2.Measurement:3 DC circuits electrical parameters,4DI2DO,4 temp.,1 leakage current,1 temp. and humidity

3.±12V output to power hall current sensor

4.Communication:1 in 1 out type RJ45 interface(Modbus protocol)

AC bus connector temp. measurement device 11 AMB200-LRAMB200-C 1.Installation: Fixed on the cover of the busbar connection

2.Contact temp. measurement,measure and display temp. of 4 AC busbars

3.Communication:RS485 or LoRa

DC outgoing line hall effect current sensor  12 AHKC-BS Current ratio:100A/5VCommon Specification: 100A/5V

Human Machine Interface

13
14

Photos on site

15
16
18