• head_banner

Medical Isolation Power Supply System

Medical Isolation Power Supply System

Application

Medical IT system insulation monitoring device and fault location system is suitable for hospital operating room, ICU (CCU) and other important places, and can provide a safe place for such continuous, reliable power solutions.

Structure

1

Main Functions

1)Primary connection diagram and field distribution display

2
3

2)Real-time data acquisition and display

4

3)Fault Alarm

5

4)Remote parameter setting and inquiry

6

5)Graphic display

Display the insulation status, load status, and the isolation transformer temperature of each set of isolated power systems in graph form.

Product Selection

1)AITR Series Medical isolation transformer

7

•Isolating transformers for medical IT systems
•Double insulation treatment, Electrostatic shielding layer
•PT100 temperature sensor
•Rated power: 3.15…10KVA
•CE mark

2)AIM-M10 Medical Intelligent Insulation Monitor

8

• Insulation monitoring for medical IT systems
• Load and temperature monitoring of isolation transformer
• Device disconnection monitoring
• LED indicators: On, Insulation, Overload, Overtemp
• Alarm relay output
• Test button
• RS485,MODBUS-RTU

3)AIM-M100 Medical Intelligent Insulation Monitor

9

•Insulation monitoring for medical IT systems
•Load and temperature monitoring of isolation transformer
•Device disconnection monitoring
•LED indicators: On, Insulation, Overload, Overtemp
•Alarm relay output
•Test button
•RS485,MODBUS-RTU

4)AIM-M200 Medical Intelligent Insulation Monitor

10

•Insulation monitoring for medical IT systems
•Load and temperature monitoring of isolation transformer
•Device disconnection monitoring
•LED indicators: On, Insulation, Overload, Overtemp
•Alarm relay output
•Test button
•Insulation fault location
•RS485 (MODBUS-RTU) + CAN (custom protocol)

5)AID10 Alarm and Display Instrument

11

•Remote monitoring
•LED indicators:On, Insulation, Overload, Overtemp
•Mute button
•Test button
•Power supply: DC24V
•RS485,MODBUS-RTU

6)AID120 Alarm and Display Instrument

12

•Remote monitoring
•LED indicators:On, Insulation, Overload, Overtemp
•Mute button
•Test button
•Power supply: DC24V
•RS485,MODBUS-RTU

7)AID150 Alarm and Display Instrument

13

•Remote monitoring
•LED indicators:On, Insulation, Overload, Overtemp
•Mute button
•Test button
•Power supply: DC24V
•RS485,MODBUS-RTU

8)ACLP10-24 DC Power Supply

14

•Power Supply to AID series
•AC 220V input, DC 24V output
•Completely Isolated Linear Transformer
•Power-on indicator

9)ASG150 Signal Generator 

15

•Generating Fault Location Signal
•Detection of L1 and L2 disconnection
•LED indicators: On, Comm, L1, L2, Fault
•CAN bus, custom protocol
•Power supply: DC24V

10)AIL150-4/-8 Insulation Fault Locator

16
17

•Insulation fault location in AC IT systems
•AIL150-4: 4 measuring channels
•AIL150-8: 4 measuring channels
•LED indicators: On, Comm, L1…L8
•CAN bus, custom protocol
•Power supply: DC24V

Typical Solution

1)Four-piece set

18

2)Five-piece set

19

3)Seven-piece set

20

Photos on site

f9725a374d4c058ab3f9d172c98c346
23