AM5SE series microcomputer protection measurement and control device (hereinafter referred to as the device) integrates protection, control, measurement, communication and monitoring functions, with rich resources, perfect configuration, convenient maintenance and stable performance, suitable for protection and measurement and control of power systems with voltage levels of 35kV and below , Realize the protection of incoming line, main transformer, distribution transformer, motor, capacitor, bus tie, PT, enz. De toepassingsvelden hebben betrekking op elektrische stroom, waterbehoud, transport, aardolie, chemische industrie, steenkool, metallurgie en andere industrieën.
Het hardware -ontwerp van het apparaat hanteert de betrouwbaarheidsconfiguratie en de software is uitgerust met een speciaal beschermingsalgoritme. Het heeft sterke anti-interferentieprestaties, hoge betrouwbaarheid en flexibele methoden voor implementatie van bescherming. Het kan worden gebruikt in combinatie met het Acrel-2000Z-stroombewakingssysteem om garantie te bieden voor de veilige en betrouwbare werking van het voedingssysteem. .
Rijke beschermingsfuncties
Feeder -bescherming;
Transformatorbescherming;
Supervisie van spanningstransformator en parallelle verbinding
Motorische differentiële bescherming;
Motorbescherming;
Capactior bescherming;
Busbindbeveiliging;
Back -upbeveiliging van transformator;
Transformator differentiële bescherming
Meting
RMS huidige waarden;
RMS -spanningswaarden;
frequentie;
Vermogensfactor;
RMS Active Power. RMS reactieve kracht.





AM5SEFunctie | -F | -T | -M | -B | -C | -Md | -D2 | -D3 | -Tb | -IS | -K | -Ub |
Overstroom (met Compound spanning afhankelijk, 3 fasen) | √ | √ |
| √ |
|
|
|
| √ | √ |
|
|
Directionele overstroom (met spanningsafhankelijk, , , ", , , , , , , , , , , , , , ,3 fasen) | √ |
|
| √ |
|
|
|
| √ | √ |
|
|
Differentieel met beperkende verhouding |
|
|
|
|
| √ | √ | √ |
|
|
|
|
Onmiddellijk differentieel |
|
|
|
|
| √ | √ | √ |
|
|
|
|
CT toezicht | √ | √ |
|
|
| √ | √ | √ |
| √ |
|
|
Overstroom (2 fasen) |
|
| √ |
| √ | √ |
|
|
|
|
|
|
Directionele aardfout (I01, 2 fasen) | √ |
|
| √ |
|
|
|
| √ | √ |
|
|
Directionele Earth Fault (i02, 2 fasen) | √ |
|
|
|
|
|
|
|
| √ |
|
|
2 Stages Earth Fault (I01) |
| √ | √ |
| √ | √ |
|
|
|
|
|
|
2 Stage Earth Fault (I02) |
| √ |
|
|
|
|
|
|
|
|
|
|
Overstroom IDMT (normaal inverse, zeer omgekeerd, extreem omgekeerd) | √ | √ | √ | √ | √ | √ |
|
| √ | √ |
|
|
Earth Fault Idmt (I01) | √ | √ |
|
|
|
|
|
| √ | √ |
|
|
Earth Fault Idmt (I02) | √ | √ |
|
|
|
|
|
|
| √ |
|
|
Opruiming nulVolgorde bescherming(2 fasen) |
|
|
|
|
|
|
|
| √ |
|
|
|
Positieve reeks overstroom (2 fasen) |
|
|
|
|
| √ |
|
|
|
|
|
|
Positieve reeks overstroom IDMT |
|
|
|
|
| √ |
|
|
|
|
|
|
Negatieve volgorde overstroom (2 fasen) |
|
| √ |
|
| √ |
|
|
|
|
|
|
Negatieve reeks overstroom IDMT |
|
| √ |
|
| √ |
|
|
|
|
|
|
Overladen | √ | √ | √ |
|
| √ |
|
| √ | √ |
|
|
Beginnende luchtgekoelde waterkoeler |
|
|
|
|
|
|
|
| √ |
|
|
|
Tap-load-wisselaar Lock Out |
|
|
|
|
|
|
|
| √ |
|
|
|
TRIP EN SLUIT CIRCUITSOPPULTION (Alarm) | √ | √ | √ | √ | √ | √ |
|
| √ | √ |
|
|
Onderspanning (reis) | √ |
| √ |
| √ | √ |
|
|
| √ |
|
|
Onderspanning (alarm) | √ |
|
|
|
|
|
|
|
| √ |
| √ |
PT -toezicht | √ | √ | √ | √ | √ | √ |
|
| √ | √ |
| √ |
Drie fase automatische herstel | √ |
|
|
|
|
|
|
|
| √ |
|
|
Onder frenquency | √ |
|
|
|
|
|
|
|
| √ |
|
|
Over de frequentie | √ |
|
|
|
|
|
|
|
| √ |
|
|
Na versnelde overstroom | √ |
|
| √ |
|
|
|
|
| √ |
|
|
Overspanningsbeveiliging | √ |
| √ |
| √ | √ |
|
|
| √ |
| √ |
Rotor blokkeren |
|
| √ |
|
| √ |
|
|
|
|
|
|
Onbalansspanning |
|
| √ |
| √ | √ |
|
|
|
|
|
|
Onbalansstroom |
|
|
|
| √ | √ |
|
|
|
|
|
|
Resterende overspanningsbeveiliging | √ |
|
|
| √ | √ |
|
| √ | √ |
|
|
Resterende overspanning (alarm) |
|
| √ |
|
|
|
|
|
|
|
| √ |
Positieve reeks overspanningsbeveiliging |
|
|
|
|
| √ |
|
|
|
|
|
|
Negatieve reeks overspanningsbeveiliging |
|
|
|
|
| √ |
|
|
|
|
|
|
Niet-elektriciteit | √ | √ | √ |
| √ | √ |
|
| √ | √ |
|
|
Starttijd |
|
| √ |
|
| √ |
|
|
|
|
|
|
Directionele kracht | √ |
|
|
|
|
|
|
|
| √ |
|
|
Thermische overbelasting |
|
| √ |
|
| √ |
|
|
|
|
|
|
Onjuiste fasevolgorde |
|
| √ |
|
| √ |
|
|
|
|
|
|
Spanningsfase verlies |
|
| √ |
|
| √ |
|
|
|
|
|
|
Bus Tie Bescherming en standby -power automatische schakelaar |
|
|
| √ |
|
|
|
|
|
|
|
|
FC -blok | √ | √ | √ |
|
| √ |
|
| √ | √ |
|
|
PT -toezicht en parallelle verbinding |
|
|
|
|
|
|
|
|
|
|
| √ |
Zelf geproduceerdnul over de huidige bescherming |
|
|
|
|
|
|
|
| √ |
|
|
|
Synchro-controle | √ |
|
| √ |
|
|
|
|
| √ |
|
|
Mate van frequentieverandering |
|
|
|
|
|
|
|
|
| √ |
|
|
Auto-close met spanningsherstel |
|
|
|
|
|
|
|
|
| √ |
|
|