Measurement: 3-phase AC Current

Accuracy: Class 0.5

Input: 0~1A/0~5A AC

Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC

Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

Wiring: 3-phase 3-wire

Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

Response Time: 400ms

Installation: 35mm DIN Rail/Screw fixed

Standard&Certificate: CE


Product Detail

PARAMETERS

Download

Overview

BD-3I3 series Electricity Transducer can measure Voltage, Current, Power, Power factor, Frequency; 1.2 times of rated value overload; DC 0-5V/0-10V/0-20mA/4-20mA all can be choosed as analog output.

Intelligent Matching

① Record storage analog output record

② Provide analog output signal to PLC

③ Provide analog output to frequency converter

④ Provide analog output for digital display meter

1

Features

① The measuring transmitter is designed to convert AC electric signal into analog signal or digital signal in accordance with GB / T 13850

② High accuracy class: 0.5

③ Full electric parameter measurement, freely combined transmission output type

④ The true RMS measurement is suitable for occasions with large harmonics, voltage and current waveform distortion and other harsh environments

⑤ It can be worked with RS485 communication interface and connect on the same 485 bus with the control module of other manufacturers, which is convenient for

computer programming. Users can easily build their own measurement and control system

⑥ It can be worked with external display module, and the customer can directly change the input range and transmission type on site

⑦ Optional transformer built-in perforated installation type, convenient for construction wiring and cost saving

2

Specifications

e47481eea93f76ab69f3cf3d33bd9c2e

Application

3

Technical parameters Value
Accuracy class 0.5 、0.2
  

 

 

 

Input

 Nominal value (Current)AC DC 1A 5A(Voltage)AC DC 100V 300V 500V
 Overload Continual 1.2 times, Instantaneous current 10 times/5s;Instantaneous voltage 2 times/30s;
  Consumption ≤0.3VACurrent input)Voltage input, ≤0.3VA( 100V 时) 0.6VA(300V 时) 1VA(500V 时)
 Frequency 50±5Hz ,60±5Hz
  Output  Normal value DC:4-20mA 0-20mA, 0-5V, 0- 10V (And so on)
 

 Load resistance

(Current output)600Ω(Voltage output)1000Ω
 Ripple content <0.5%(peak value)
Response time 400ms
Power supply  Voltage AC85-265V 、DC100-350V
 Consumption (AC current, voltage)≤3VA, (Power)≤4VA
Insulation resistance 100MΩ
 Isolation voltage (Among input//output//power supply) 2.0kV/ 1min, 50Hz
Temperature modulus 200ppm/
 

Environment

 Temperature (Work)- 10~+55(Storage): -25~+70
 Humanity  (In the place without dew and corrosive gas)
 Altitude 2000m